jump cable Lexus GS300h 2017 Owner's Manual

Page 530 of 600

5307-2. Steps to take in an emergency
GS450h_300h_OM_OM30F92E_(EE)
If the 12-volt battery is discharged
If you have a set of jumper (or booster) cables and a second vehicle with a 12-volt
battery, you can jump start your vehicle by following the steps below. Confirm that the electronic key is
being carried.
When connecting the jumper (or
booster) cables, depending on the situa-
tion, the alarm may activate and doors
locked. ( P. 93)
Open the hood ( P. 401), remove
the engine compartment covers (  P. 405) and open the fuse box
cover.
Remove all of the clips.
Push the tabs on either side to
detach the lock and lift the lid off
while pulling the lock plate.
Open the exclusive jump starting
terminal cover.
The following procedures may be used to start the hybrid system if the 12-volt
battery is discharged.
You can also call any authorized Lexus retailer or Lexus authorized repairer,
or any reliable repairer.
1
2
1
2
3

Page 531 of 600

531
7-2. Steps to take in an emergency
7
When trouble arises
GS450h_300h_OM_OM30F92E_(EE) GS450h: Remove the engine cover.
Connect the jumper cables according to the following procedure:
GS450h
GS300h
4
5

Page 532 of 600

5327-2. Steps to take in an emergency
GS450h_300h_OM_OM30F92E_(EE) Connect a positive jumper cable clamp to the exclusive jump starting ter-
minal on your vehicle.
Connect the clamp on the other end of the positive cable to the positive (+)
battery terminal on the second vehicle.
Connect a negative cable clamp to the negative (-) battery terminal on the
second vehicle.
Connect the clamp at the other end of the negative cable to a solid, station-
ary, unpainted metallic point away from the exclusive jump starting terminal
and any moving parts, as shown in the illustration.
Start the engine of the second vehicle. Increase the engine speed slightly and
maintain at that level for approximately 5 minutes to recharge the 12-volt bat-
tery of your vehicle.
Open and close any of the doors of your vehicle with the power switch off.
Maintain the engine speed of the second vehicle and start the hybrid system
of your vehicle by turning the power switch to ON mode.
Make sure the “READY” indicator come s on. If the indicator does not come
on, contact any authorized Lexus retailer or Lexus authorized repairer, or any
reliable repairer.
Once the hybrid system has started, remove the jumper cables in the exact
reverse order from which they were connected.
Once the hybrid system starts, have the vehicle inspected at any authorized
Lexus retailer or Lexus authorized repairer, or any reliable repairer as soon as
possible.
1
2
3
4
6
7
8
9
10

Page 533 of 600

533
7-2. Steps to take in an emergency
7
When trouble arises
GS450h_300h_OM_OM30F92E_(EE)
■Starting the hybrid system when the 12-volt battery is discharged
The hybrid system cannot be started by push-starting.
■To prevent 12-volt battery discharge
●Turn off the headlights and the audio system while the hybrid system is off.
●Turn off any unnecessary electrical componen ts when the vehicle is running at a low
speed for an extended period, such as in heavy traffic.
■Charging the 12-volt battery
The electricity stored in the 12-volt battery will discharge gradually even when the vehicle
is not in use, due to natural discharge and the draining effects of certain electrical appli-
ances. If the vehicle is left for a long time, the 12-volt battery may discharge, and the
hybrid system may be unable to start. (The 12-volt battery recharges automatically while
the hybrid system is operating.)
■When recharging or replacing the 12-volt battery
●In some cases, it may not be possible to unlock the doors using the smart entry & start
system when the 12-volt battery is discharged. Use the wireless remote control or the
mechanical key to lock or unlock the doors.
●The hybrid system may not start on the first attempt after the 12-volt battery has
recharged but will start normally after the second attempt. This is not a malfunction.
●The power switch mode is memorized by the vehicle. When the 12-volt battery is
reconnected, the system will return to the mode it was in before the 12-volt battery was
discharged. Before disconnecting the 12-v olt battery, turn the power switch off.
If you are unsure what mode the power switch was in before the 12-volt battery dis-
charged, be especially careful when reconnecting the 12-volt battery.
WARNING
■Avoiding 12-volt battery fires or explosions
Observe the following precautions to prevent accidentally igniting the flammable gas
that may be emitted from the 12-volt battery:
●Make sure each jumper cable is connected to the correct terminal and that it is not
unintentionally in contact with any other than the intended terminal.
●Do not allow the other end of the jumper cable connected to the “+” terminal to come
into contact with any other parts or metal surfaces in the area, such as brackets or
unpainted metal.
●Do not allow the + and - clamps of the jumper cables to come into contact with each
other.
●Do not smoke, use matches, cigarette lighters or allow open flame near the 12-volt
battery.

Page 534 of 600

5347-2. Steps to take in an emergency
GS450h_300h_OM_OM30F92E_(EE)
WARNING
■12-volt battery precautions
The 12-volt battery contains poisonous and corrosive acidic electrolyte, while related
parts contain lead and lead compounds. Observe the following precautions when han-
dling the 12-volt battery:
●When working with the 12-volt battery, always wear safety glasses and take care not
to allow any 12-volt battery fluids (acid) to come into contact with skin, clothing or the
vehicle body.
●Do not lean over the 12-volt battery.
●In the event that 12-volt battery fluid comes into contact with the skin or eyes, immedi-
ately wash the affected area with water and seek medical attention.
Place a wet sponge or cloth over the affected area until medical attention can be
received.
●Always wash your hands after handling the 12-volt battery support, terminals, and
other battery-related parts.
●Do not allow children near the 12-volt battery.
■After recharging the 12-volt battery
Have the 12-volt battery inspected at any authorized Lexus retailer or Lexus autho-
rized repairer, or any reliable repairer as soon as possible.
If the 12-volt battery is deteriorating, continued use may cause the 12-volt battery to
emit a malodorous gas, which may be detrimental to the health of passengers.
■When replacing the 12-volt battery P. 414
NOTICE
■When handling jumper cables
When connecting the jumper cables, ensure that they do not become entangled in the
cooling fans or belt.
■To prevent damaging the vehicle
The exclusive jump starting terminal is to be used when charging the 12-volt battery
from another vehicle in an emergency. It cannot be used to jump start another vehicle.